Description:

Sets or clears the FM5004 alarm latches.

There is a separate alarm latch for each of the three

alarms: line 1 alarm, line 2 alarm, and 4-probe/3-axis

alarm

Syntax:

ALAT,m,x

Parameters:

Alarm mode (m):

• 0 = 4-probe/3-axis alarm latch

• 1 = line 1 alarm latch

• 2 = line 2 alarm latch

Numeric value (x):

• 0 = latch disabled (clear)

• 1 = latch enabled (set)

Example:

• To set the line 1 alarm latch:

ALAT,1,1

• To verify the latch status:

ALAT,1?

• If the latch is set, the FM5004 will return:

ALAT,1,1