Safety and emc standards power, Thermal environment mechanical environment – Dell PowerVault 132T LTO/SDLT (Tape Library) User Manual
Page 84
Safety and EMC Standards
Power
Thermal Environment
Mechanical Environment
Non-Operating Shock and Vibration
Operating Shock and Vibration
Safety
CSA Standard CAN/CSA-C22.2 no. 950-95
UL Standard 1950, Third Addition
EN60950
Emissions FCC #47, Part 15, Subpart B, Class A;
ICES-003 (Canada);VCCI Class A (Japan);
BSMI CNS 13438 (Taiwan);
EN55022:1994; EN61000-3-2:2001;
EN61000-3-3:1998 (Europe);
AS/NZS 3548:1995 (Australia/NZ)
Immunity EN 55024:1998 ITE – Immunity Characteristics, Limits & Methods of Measurement;
European Union CE Immunity Standards
Input Power
100–240 VAC, 50–60 Hz, 4.0–1.7 A
Power
Consumption
(includes barcode
scanner,
RMU, SCSI
Terminators)
RMS Power
(W)
Peak Power
(W)
LTO-1
LTO-2
LTO-3
SDLT
LTO-1
LTO-2
LTO-3
SDLT
One Drive
104
89
76
104
162
147
122
157
Two Drives
179
149
123
179
290
260
210
280
Two Drives with
SNC
253
223
197
253
376
346
296
366
Operating
Non-operating
Shipping & Storage
Dry Bulb Temperature 10ºC to 38ºC
(50ºF to 100ºF)
@2000 M
10ºC to 33ºC
(50ºF to 91ºF)
@3000 M
10ºC to 45ºC
(50ºF to 113ºF)
-40ºC to 65ºC
(-40ºF to 149ºF)
Temperature Variation 3ºC (5.5ºF)
per Minute Max
3ºC (5.5ºF)
per Minute Max
3ºC (5.5ºF)
per Minute Max
Wet Bulb Temperature 29ºC (84ºF)
Max
32ºC (90ºF)
Max
37ºC (99ºF)
Max
Relative Humidity
10 to 90%
10 to 90%
10 to 95%
Swept Sine
Range
Peak G
Desktop & Rackmount 3-500-3
1.0
Random Vibration
Frequency
G2/Hz
Desktop &
Rackmount
2
4
8
40
55
70
200
500
1.0x10 -3
3.0x10 -2
3.0x10 -2
3.0x10 -3
1.0x10 -2
1.0x10 -2
1.0x10 -3
1.0x10 -3
Shock
Pulse Amplitude (G) Pulse Width
Desktop
V
H
Rackmount
V
H
150
100
100
100
2
2
3
3