Show rmon alarm-table – Dell PowerEdge M805 User Manual
Page 418
410
RMON Commands
www
.dell.com | support.dell.com
Rising Event: 1
Falling Event: 1
Owner: CLI
The following table describes the significant fields shown in the display:
show rmon alarm-table
Use the show rmon alarm-table command in User EXEC mode to display the alarms summary
table.
Field
Description
Alarm
Alarm index.
OID
Monitored variable OID.
Last Sample Value
The statistic value during the last sampling period. For example, if the sample
type is delta, this value is the difference between the samples at the beginning
and end of the period. If the sample type is absolute, this value is the sampled
value at the end of the period.
Interval
The interval in seconds over which the data is sampled and compared with the
rising and falling thresholds.
Sample Type
The method of sampling the variable and calculating the value compared
against the thresholds. If the value is absolute, the value of the variable is
compared directly with the thresholds at the end of the sampling interval. If the
value is delta, the value of the variable at the last sample is subtracted from the
current value, and the difference compared with the thresholds.
Startup Alarm
The alarm that may be sent when this entry is first set. If the first sample is
greater than or equal to the rising threshold, and startup alarm is equal to rising
or rising and falling, then a single rising alarm is generated. If the first sample is
less than or equal to the falling threshold, and startup alarm is equal falling or
rising and falling, then a single falling alarm is generated.
Rising Threshold
A sampled statistic threshold. When the current sampled value is greater than
or equal to this threshold, and the value at the last sampling interval is less than
this threshold, a single event is generated.
Falling Threshold
A sampled statistic threshold. When the current sampled value is less than or
equal to this threshold, and the value at the last sampling interval is greater
than this threshold, a single event is generated.
Rising Event
The event index used when a rising threshold is crossed.
Falling Event
The event index used when a falling threshold is crossed.
Owner
The entity that configured this entry.