Continuous output formats – Cardinal Industries 225 WEIGHT INDICATOR User Manual
Page 99
CONTINUOUS OUTPUT FORMATS
displayed
G = Gross, T = Tare, N = Net
oint
xxxxxx.xxx = Weight
Six digits
Added to string if enabled in setup
ross, N = Net
f zero
SMA
Where:
lf =
Line Feed
s =
Flags
Z= center of Zero, O = Over cap, E = zero Error,
e = weight not currently being
r =
Range
1, 2, 3, ...
n =
Mode
m =
Motion
M = Motion, " "(blank) = no motion
f =
Custom
Custom flag
xxxxxx.xxx = Weight
Six digits with decimal p
uuu =
Units
ton, lb, oz, t, kg, g
cr =
Carriage Return
(hex 0D)
SB-400
Where:
s =
Sign
"-" = negative, " " (blank) = positive
d =
Decimal point
uu =
Units
tn, lb, oz, t, kg, g
m =
Mode
G = G
cc =
Weight Status
OC = over capacity
CZ = center o
MO = motion
ee = weight not currently being displayed
cr =
Carriage Return
(hex 0D)
8200-M538-O1
y 225 Installation
Page 95