Installation, cont, Main pc board i/o functions table, Relay box cable wire number to relay number table – Cardinal Industries 225 WEIGHT INDICATOR User Manual
Page 23
![background image](/manuals/60136/23/background.png)
INSTALLATION, CONT.
Main PC Board I/O Functions Table
Refer to Figure No. 8 for the AC Input Relay board, Figure No. 9 and Figure No. 10 for the AC
Output Relay boards and Figure No. 11 for the Main PCB.
INPUTS OUTPUTS
PWC
CHECKWEIGHER
DFC BATCHER
P17
INPUTS
P15
Presets
Check 3
Check 5
Fill 1
Fill 2
Batch 1
Batch 2
2
ZERO
2
PWC 1
Under
Under
Fill
Fast
Fill 1
Fast 1
3
TARE
3
PWC 2
Accept
Lo Under
Slow
Fill 2
Slow 1
4
Gross/Net
4
PWC 3
Over
Accept
Fill 3
Fast 2
5
5
PWC 4
Lo Over
Fill 4
Slow 2
6
N/A
6
PWC 5
Over
Fill 5
Fast 3
7
STOP
7
PWC 6
Fill 6
Slow 3
8
START
8
PWC 7
Fill 7
9
DUMP
9
PWC 8
Dump
Dump
Dump
Dump
P16
Presets
Check 3
Check 5
Fill 1
Fill 2
Batch 1
Batch 2
2
PWC 9
Under
Under
Fill
Fast
Fill 1
Fast 1
3
PWC 10
Accept
Lo Under
Slow
Fill 2
Slow 1
4
PWC 11
Over
Accept
Fill 3
Fast 2
5
PWC 12
Lo Over
Fill 4
Slow 2
6
PWC 13
Over
Fill 5
Fast 3
7
PWC 14
Fill 6
Slow 3
8
PWC 15
Fill 7
9
PWC 16
Dump
Dump
Dump
Dump
Relay Box Cable Wire Number to Relay Number Table
The relay box cable wire numbers correspond to the indicator main PC board remote input
(P17) and output (P15 and P16) terminal connection pins.
CABLE WIRE
NUMBER
RELAY NUMBER
(Set Proper Jumpers)
CABLE WIRE
NUMBER
RELAY NUMBER
(Set Proper Jumpers)
1
+SRC (For AC Input Relays)
6
5
2 1 7
6
3 2 8
7
4 3 9
8
5 4 10
GND
8200-M538-O1
y 225 Installation
Page 19