Continuous output formats, cont – Cardinal Industries 225 WEIGHT INDICATOR User Manual
Page 102
CONTINUOUS OUTPUT FORMATS, CONT.
Weight on Demand Format
If continuous output has not been selected for PRINTER or COM Ports (
CONT=NO), the 225
indicator will respond to a weight request (ENQ) as follows.
The host device (computer) sends:
The 22
Where:
s =
Sign
"-" = negative, " " (blank) = positive
Weight
Six digits
Decimal point
Added to string if enabled in setup
u
tn, lb, oz, t, kg, g
m =
Mode
G = Gross, N = Net
Weight Status
OC = over capacity
CZ = center of zero
layed
c
urn
(hex 0D)
ENQ - (hex 05)
5 will respond:
xxxxxx.xxx =
d =
u =
Units
cc =
MO = motion
ee = weight not currently being disp
r =
Carriage Ret