Id storage operation, cont – Cardinal Industries 225 WEIGHT INDICATOR User Manual
Page 88
ID STORAGE OPERATION, CONT.
P
T
DELETE key.
omentarily.
erations mode, press the MEM key. The display will
and then press the
key.
n
ermanent Identification (ID) Strings, Cont.
o Delete A Permanent ID String:
1. With the indicator in normal operations mode, press the MEM key. The display will
change to show
Id=.
2. Enter the ID string to be deleted and then press the
3. The display will show
Id deleted m
4. The ID string entered along with its associated accumulator will be deleted.
5. The indicator will return to normal operation.
To Print A Permanent ID String:
1. With the indicator in normal op
change to show
Id=.
Enter the ID string
2.
3. A ticket containing the stored weight, the accumulated weight along with the ID string
will be printed and the indicator will return to normal operation.
4. If the ID string entered does not exist, the display will show
ID NOT FOUND and the
indicator will return to normal operation.
To Delete
U
All
U
Permanent ID Strings:
1. With the indicator in normal operations mode, press the MEM key. The display will
change to show
Id=.
2. Press the DELETE key. The display will show
Del All?NO, which asks if all ID
strings are to be deleted.
s the YES key (display will change to
Del All?YES)
sociated accumulators will be deleted.
3. To delete all ID strings, pres
and then press the ENTER key.
4. All ID strings and the as
5. The indicator will return to normal operation.
To Print
U
All
U
ID Strings:
1. With the indicator in normal operations mode, press the MEM key. The display will
change to show
Id=.
2. Press the PRINT key. The display will show
Printing while all currently stored ID
strings are printed.
3. The indicator will return to normal operation.
8200-M538-O1
y 225 Installation