CALIBRATION AND SETUP, CONT.
SETU
With S
SETUP
T
e
(1) scale.
three (3) sc
referenced
wn.
he following describes the Scale Setup for the 225. The standard 225 supports on
With the optional 225-DS Dual Scale card installed, it can support up to
ales. In the setup menus shown and parameters described, Scale 1 is
. Substitute the scale number you are configuring for the number sho
P SCALE
ETUP MENU #1 displayed, press NEXT (Navigation Keys
Down Arrow) to proceed to
MENU #2.
SETUP MENU #2
1. SERIAL
2. DIO
3. PRINT TABS
4. SETUP SCALE 1
5. CALIBRATE 1
Enter Selection: 0
`
NEXT
^
PREV
4. S
With
to S
ETUP SCALE 1
the SETUP MENU #2 displayed, press the 4 key and then the ENTER key to proceed
CALE 1 SETUP MENU #1.
SCALE 1 SETUP MENU #1
1. BASE UNITS=X XX 6. SAMPLES=XXX
2. CNVT UNITS=X XX 7. STABLE=XX
3. Z TRACK=X.X 8. STBL CNT=XXX
4. Z LIMIT=XXX
9. WT INTERVALS=XX
5. PWR UP Z=XXX
Enter Selection: 0
`
NEXT
^
EXIT
1. BASE
NITS)
With S
#1 displayed the current setting for the
BASE UNITS=
param
XX is the description. If
the setting displayed is acceptable, proceed to the next setup parameter.
key and then using the numeric keys, enter the
press the ENTER key to save the new setting and
. Allowable values are 0 through 6.
UNITS=X XX (BASE U
CALE 1 SETUP MENU
eter will be shown. Note that X is the current value and
Otherwise, press the 1 key, the ENTER
value for the base units and then
return to SCALE 1 SETUP MENU #1