CALIBRATION AND SETUP, CONT.
CA
With th
procee
LIBRATE
e SETUP MENU #1 displayed, press NEXT (Navigation Keys
Down Arrow) to
d to SETUP MENU #2.
SETUP MENU #2
1. SERIAL
2. DIO
3. PRINT TABS
4. SETUP S
5. CALIBRATE 1
CALE 1
Enter Selection: 0
^
PREV
`
EXIT
5. C
With the SETUP MENU #2 displayed, press the 5 key and then the ENTER key to proceed
to S
ALIBRATE 1
CALE 1 CALIBRATION MENU.
SCALE 1 CALIBRATION MENU
1. Swt= XXXXXXX 6. C1=XXX
2. Sct= XXXXXXX 7. C2=XXX
3. Zct= XXXXXXX
8. C3=XXX
9. C4=XXX
4. FINE SPAN
5. HI RES 10. CALIBRATE
Enter Selection: 0
^
EXIT
1. Swt=XXXXXXX (SPAN WE
2. Sct=
AN COUNT)
3. Zct=XXXXXXX (ZERO COUNT)
The calibr
t and Zct) represent the test load (weight) and the
analog to digital readings at zero and test load. These values are established when the
scale is ca
tor can be returned to its
present calibration settings without using test weights simply by entering the values.
settings. Each number may be up to three digits in length. The “C” numbers are
established when the scale is calibrated. By recording these numbers, the indicator can be
returned to its present calibration settings without using test weights simply by entering the
“C” numbers.
IGHT)
XXXXXXX (SP
ation parameters (
Swt, Sc
librated. By recording the parameter values, the indica
CALIBRATION PARAMETERS
6. C1=XXX
7. C2=XXX
8. C3=XXX
9. C4=XXX
CALIBRATION “C” NUMBERS
The calibration “C” numbers (
C1, C2, C3 and C4) represent the present calibration
8200-M538-O1