Calibration and setup, cont – Cardinal Industries 225 WEIGHT INDICATOR User Manual
Page 53
![background image](/manuals/60136/53/background.png)
CALIBRATION AND SETUP, CONT.
PRINT TABS SETUP
With SETUP MENU #1 displayed, press NEXT (Navigation Keys
Down Arrow) to proc
SETUP MENU #2.
eed to
SETUP MENU #2
1. SERIAL
2. DIO
3. PRINT TABS
4. SETUP SCALE 1
5. CALIBRATE 1
Enter Selection: 0
`
NEXT
^
PREV
3. PRINT TABS (PRINT TABS SETTING)
#1.
With the SETUP MENU #2 displayed, press the 3 key and then the ENTER key to proceed
to PRINT TABBING MENU
PRINT TABBING MENU #1
1. PORT=X XXXXXXX 6. TIME=YY.XX
2. PRT BEG=XXXXXXXXXXXX 7. DATE=YY.XX
3. AUTO LF=XXX 8. CNC NO=YY.XX
X 10. TARE=YY.XX
4. ENDING LF=XX 9. GROSS=YY.XX
5. PRT END=XXXXXXXXXXX
Enter Selection: 0
`
NEXT
^
EXIT
1. PORT=X XXXXXXX (SELECT PORT FOR PRINTER)
With PRINT TABBING MENU #1 displayed the current setting for the
PORT=
parameter will be shown. Not
alue and XXXXXXX is the
descri
ng displayed is acceptable, proceed to the next setup parameter.
Otherw
e ENTER key and then using the numeric keys, enter the
value
e connected to and then press the ENTER key to save
the new setting and return to PRINT TABBING MENU #1. Allowable values are 0
throug
0 = PRINTER
1 = COM1
2 = COM2
3 = COM3
e that X is the current v
ption. If the setti
ise, press the 1 key, th
for the port the printer will b
h 3.
8200-M538-O1
y 225 Installation