CALIBRATION AND SETUP, CONT.
ndicator ON, press the SHIFT key and th
With the i
en press the Navigation ENTER key (red
square key in center of the Navigation arrows). The display will change to show the
SETUP/REVIEW MENU.
SETUP/REVIEW MENU
1.ENTER CALIBRATION AND SETUP
2.VIEW AUDIT TRAIL COUNTERS
3.CALIBRATE SCALE 1
Enter Selection: 1
^
EXIT
1. ENTER CALIBRATION AND SETUP
SETUP MENU #1
With the SETUP/REVIEW MENU displayed, press the 1 key and then the ENTER key. The
display will change to show SETUP MENU #1.
SETUP MENU #1
1. USA=XXX
6. CLR TARE=XXX
2. NSC=XXX
7. CLEAR ID=XXX
3. LFT=XXX
8. NO OF SCALES=X
4. OIML=XXX
9. TOTALIZE=XXX
5. TIME=XX
10. MODE OF OP=0 NORM
Enter Selection: 0
`
NEXT
^
EXIT
1. USA=XXX (DOMESTIC or INTERNATIONAL)
With SETUP MENU #1 displayed the current setting for the
USA= parameter will be shown.
Note that XXX is the current value. If the setting displayed is acceptable, proceed to the
next setup parameter.
Otherwise, press the 1 key, the ENTER key, YES or NO (on the soft keys) and then the
ENTER key to save the new setting and return to SETUP MENU #1.
USA=YES (Domestic)
USA=NO (International)
DATE = MM/DD/YY
DATE = DD/MM/YY
Z LIMIT = NO
Z LIMIT = YES
CAP + 5% to OC
CAP + 9 grads to OC
ETR able = YES
PT printed with tare. Lamp test on
power up. Lorry Weigher Operation
(Any MODE OF OP but 1 or 6).
NSC (Australia NSC Requirements)
setup parameter selection allowed
8200-M538-O1
y 225 Installation
Page 35