B&G Deckman User Manual
Page 114
h2000 Performance Unit
7.9
Damping
This allows you to send damping values to the instrument system. The
values are stored and are NOT read from the instruments. If you are
setting the values so that they are the same as the instrument system the
safest thing is to disconnect from the instrument system before making
changes. The values are sent to the instrument system as soon as they
are entered.
Calibration
This sends calibration values to the instrument system. It works in
exactly the same way as damping.
Bounds checking
To prevent errors caused through the loss of characters between the
instrument system and the PC, the incoming data are checked against the
previous values. This display allows you to change the bounds which are
used for each incoming variable; smaller values make errors less likely
but increase the possibility that the numbers will stick because of
dramatic boat manoeuvres.
Reset bounds checking
The next set of incoming data will overwrite the old, even if it falls
outside the error bounds.
h2000 true wind correction table
This function allows you to access and alter the Hydra and Hercules
true wind correction tables. These work as described in the h2000
manual in the section entitled "True Wind Correction".
Wake Up
Hydra and Hercules systems are instructed what data to send by the PC
each time it is turned on and Deckman requests this automatically. If
some of the responses are missing, simply press the Wake Up button to
send the instructions again.