Installing the mounting bracket, Installing the mounting bracket -5 – ClearOne DigiLinX User Manual
Page 84
DoorLinX
11-5
All specifications subject to change without notification. All rights reserved. Copyright © 2008 NetStreams
Main +1 512.977-9393 / fax +1 512.977.9398 / Toll Free Technical Support +1 866-353-3496
3600 W. Parmer Lane, Suite 100; Austin, TX 7872
You can use a 16/2 or 14/2 cable since two wires on the 16/4 cable are clipped and
not used. However, using the 16/4 or 14/4 cable allows for easy future expansion or
upgrades.
3.
Connect two 20 AWG cables from the DoorLinX DOORBELL 2-pin Phoenix port
to the two screws on the back of the doorbell.
4.
If you are installing a remote door latch, connect three 20 AWG cables from the
DoorLinX CONTACT CLOSURE 3-pin Phoenix port to the contact connections of
the latch. Follow the remote relay’s manual for complete cable configuration.
Installing the Mounting Bracket
Although the DX100 fits into a standard backless 2-gang box (mounted horizontally),
use the provided DXB100 mounting bracket to ensure a good fit and seal with the
faceplate. The mounting bracket provides the flexibility of either being installed during
new home construction or being retrofitted into an existing home. You can place
exterior materials such as rock or stucco around the mounting bracket after it has been
installed.
The optimal position for the mounting bracket is at least 54” high and within 5’ of
either side of the door frame. To install the mounting bracket, complete the following
steps as shown in Figure 11-4:
1.
Position the bracket with the mounting tab vertical against a stud.
2.
Screw the mounting bracket most of the way into the stud with wood screws.
3.
Slide the mounting bracket forward or back on the screw hole rails to adjust the
mounting bracket to the appropriate depth to be flush with the wall.
4.