To pre-wire for IP-Based video, complete the following steps:
1.
Install a four-port flush mounted wall plate (with CAT5e and RG6 connections) at
the video location.
NOTE:
If you are installing a home theater system, also install a four-port flush mounted wall
plate (with CAT5e and RG6 connections) near the theater equipment.
2.
From the head end, run the structured cable to the four-port flush mounted wall
plate.
3.
From the head end, run a 16/4 cable for power.
4.
Terminate using 568A terminations on the CAT5e cables.
5.
Terminate F type connections on the RG6 cables.
NOTE: