Installing free standing, Led indicators, Installing a pl250 or pl228 – ClearOne DigiLinX User Manual
Page 72: Installing free standing -5 led indicators -5, Installing a pl250 or pl228 -5
PowerLinX
9-5
All specifications subject to change without notification. All rights reserved. Copyright © 2008 NetStreams
Main +1 512.977-9393 / fax +1 512.977.9398 / Toll Free Technical Support +1 866-353-3496
3600 W. Parmer Lane, Suite 100; Austin, TX 7872
2.
Place the PowerLinX on the PL50/PL51.
NOTE:
If only one PowerLinX is being used, then two blank faceplates are needed to cover
the open spaces. The PL51 comes with two blank faceplates.
3.
Install the PL10 blank plate to cover any open spaces.
4.
Terminate all power wires to the Phoenix connectors (ensure polarity is correct).
5.
Plug the PowerLinX into the AC outlet.
Note that a minimum of six
SpeakerLinX can be used on each power supply with a
maximum of one SpeakerLinX per port. This leaves two extra ports for other devices.
Installing Free Standing
1.
Terminate all power wires to the Phoenix connectors (ensure polarity is correct).
NOTE:
To avoid heat build-up, ensure all electronics have a minimum of 1 cubic ft. of air
space.
2.
Plug the PowerLinX into the AC outlet.
LED Indicators
The LEDs on the PL600 and PL750 front panel indicate status for each of the eight
power connections on the unit. These LEDs identify any problems with power from the
PowerLinX. The following are the indications used:
Green
Active/OK
Amber
Potential Current Overdraw
Red
Current Overdraw.
Installing a PL250 or PL228
To install the PL250 or PL228, complete the following steps:
NOTE:
Ensure the polarity is correct. Look on the bottom of the PowerLinX to determine
which wire is negative and which is positive.
1.
Attach a two-pin Phoenix connector to the cable from the PL250 or PL228.
2.
Plug it into a SpeakerLinX, ControLinX, MediaLinX, or TouchLinX.
3.
Turn on the PL250 or PL228.