Banner PresencePLUS Pro COLOR—PROII Camera User Manual
Page 58

Comments
Optional
Qualifiers
Required
Qualifiers
Support Actions
Object or
Activity
Identifier
System Object,
Component, or
Activity
Retrieve currently
running inspection
None
None
GET
INSPNUM
Current
Inspection
Number
Retrieve comm
tool results, either
CommTool
Numberor
None
GET
COMMTOOL
Communications
Tool Results
by specifying its
CommTool
Name
sequential number
in the inspection
(1,2,..,n) or by
specifying its
name. By default,
data for the first
comm tool will be
retrieved.
Retrieve the value
of the Pass/Fail
None
None
GET
PASSFAILFLG
Pass/Fail flag
fl
ag - 1 if pass, 0 if
fail
Retrieve the value
of the System
None
None
GET
SYSERRFLG
System Error
Error - either 0 or
1
Retrieve the
current frame
number
None
None
GET
FRAMENUM
Frame Number
Retrieve the pass
count
None
None
GET
PASSCNT
Pass Count
Retreive the failed
count
None
None
GET
FAILCNT
Fail Count
Retrieve the
Iteration Count
None
None
GET
ITERCNT
Iteration Count
Retrieve the
system error count
None
None
GET
SYSERRCNT
System Error
Count
Retrieve the
missed trigger
count
None
None
GET
MISSTRIGCNT
Missed Trigger
Count
Retrieve the
cached status of
the I/O line
None
I/O line id,
numeric, either 1
through 4 or 1
through 6
GET
IOSTS
I/O Line Status
Retrieve the gain
None
GET
GAIN
Gain
Set the gain
None
Positive Integer
SET
GAIN
Gain
Retrieve the
camera exposure
None
GET
EXPOSURE
Exposure
Banner Engineering Corp.
Minneapolis, MN USA
58
2/2010
System Setup Dialog