Product change, 1 product change specifications, 2 product select input specifications – Banner PresencePLUS Pro COLOR—PROII Camera User Manual
Page 353: 3 proii product select, Chapter 11: product change, Chapter 11 product change
![background image](/manuals/587798/353/background.png)
Chapter 11
Product Change
This section explains the Product Change ( line 15) input.
The Product Change input is used in conjunction with one of the four I/O points programmed as Product Select lines.
The inspection loaded will be executed following a valid trigger.
• The Product Change input responds to the leading edge transition of a pulse greater than 1 millisecond.
• The Product Select input is pulsed to correspond to a program location. For example, five pulses will load program
#5.
11.1 Product Change Specifications
Current Sourcing (PNP)
Current Sinking (NPN)
State
> 8V at -7.5 mA max.
< 2V at 1 mA max.
ON
< 2V at -7.5 mA max.
> 10 V at 4 mA max.
OFF
11.2 Product Select Input Specifications
Current Sourcing (PNP)
Current Sinking (NPN)
State
> 8V at -7.5 mA max.
< 2V at 1 mA max.
ON
< 2V at -7.5 mA max.
> 10V at 4 mA max.
OFF
11.3 ProII Product Select
The Pro II has four dedicated Product Select lines that can be thought of as making a BCD table. You can access
inspections 0-15 using the following pin combinations.
Product Select #0
Product Select #1
Product Select #2
Product Select #3
Inspection Number
OFF
OFF
OFF
OFF
0*
ON
OFF
OFF
OFF
1
OFF
ON
OFF
OFF
2
ON
ON
OFF
OFF
3
OFF
OFF
ON
OFF
4
ON
OFF
ON
OFF
5
OFF
ON
ON
OFF
6
ON
ON
ON
OFF
7
OFF
OFF
OFF
ON
8
ON
OFF
OFF
ON
9