beautypg.com

Rockwell Automation MPMA Integrated Multi-Axis Linear Stages User Manual

Page 113

background image

Rockwell Automation Publication MPMA-UM001B-EN-P - November 2010

113

Interconnect Diagrams

Appendix C

Figure 16 - Wiring Examples for MP-Series Integrated Linear Stages and Kinetix

6000 Drives

D

C

B

A

BR+

BR-

F

G

W

V

U

0
1
2
3
4
5
6
7
8
9

10
11
12
13
14
15

SIN+

SIN-

COS+

COS-

DATA+

DATA-

+5VDC

ECOM

GREEN

WHT/GREEN

GRAY

WHT/GRAY

BLACK

WHT/BLACK

RED

WHT/RED

3
4

5
6

1
2

9

10

1
2

3
4

5

10

14

6

14

12

+9VDC

TS+

ORANGE

WHT/ORANGE

11
13

7

11

4

3

2

1

6

5

4

3

2

1

Green/Yellow

Blue

Black

Brown

Black

White

GND

W

V

U

GND

Shield

W

V

U

MBRK -

MBRK +

COM

PWR

DBRK -

DBRK +

BR+

BR-

TS-

COM

BLUE

AM+

AM-

BM+

BM-

IM+

IM-

+5VDC

ECOM

BLUE

WHT/BLUE

GREEN

WHT/GREEN

GRAY

WHT/GRAY

BLACK

WHT/BLACK

RED

WHT/RED

1
2

3
4

5

10

14

6

12

TS-

S1

TS+

ORANGE

WHT/ORANGE

11

S2
S3

COM

YELLOW

WHT/YELLOW

13

8

3
4

5
6

1
2

14
15
16
17
12

11
13

9

10

D

C

B

A

User Supplied
24V dc (1.2A max.)

BALL SCREW STAGES WITH

HIGH RESOLUTION FEEDBACK

MPAS-A/Bxxxx-V05SxA and

MPAS-A/Bxxxx-V20SxA

2090-XXNPMF-xxSxx

Motor Power Cable

Note 3

Thermostat

Three-Phase
Motor Power

Brake

KINETIX 6000

IAM (inverter) or AM

Note 2

Cable Shield

Clamp

Note 1

Motor Power

(MP) Connector

Motor/Resistive
Brake (BC) Connector

Resistive Brake
Connections

Motor Feedback

(MF) Connector

(IAM/AM)

2090-XXNFMF-Sxx Feedback Cable

Notes 3, 4

Motor

Feedback

Motor Feedback
(MF) Connector

DIRECT DRIVE STAGES WITH

INCREMENTAL FEEDBACK

MPAS-A/Bxxxx-ALMx2C

Thermostat

Three-Phase
Motor Power

Motor Feedback

(MF) Connector

(IAM/AM)

Refer to Low Profile Connector

illustration (lower left)

for proper grounding technique.

Exposed shield secured

under clamp

Clamp

Turn clamp over to hold

small cables secure

Clamp screw

Low Profile Connector
(2090-K2CK-D15xx shown)

Grounding Technique for

Feedback Cable Shield

Connection to Drive

2090-XXNFMF-Sxx Feedback Cable

Notes 3, 4

Motor

Feedback

Refer to Low Profile Connector

illustration (lower left)

for proper grounding technique.

2090-XXNPMF-xxSxx

Motor Power Cable

connects to Motor Power (MP)

and Cable Shield Clamp

as shown above