Rockwell Automation 6185-V Industrial 18.1 Inch Flat Panel Monitor User Manual User Manual
Page 62

62
Industrial 18.1" Flat Panel Monitor
Publication 6185-UM001B-EN-P
Electrical
Ground Leakage
1.0 uA max at 1.5 KVDC
Power Consumption
65W max, 75 VA max
Environmental
Versa Mount Option Rating
NEMA 1 (IP30 equivalent)
Operating Temperature
0C to 40C
Storage Temperature
-20C to 65C
Relative Humidity
10% to 85% non-condensing
Operating Altitude
Sea level to 10,000 ft (3048m)
Non-Operating Altitude
Sea level to 25,000 ft (7620m)
Operating Electrostatic
Discharge
8.0K VDC (IEC 801-2, level 3)
Non-Operating Electrostatic
Discharge
20.0K VDC
Operating Shock
10g (1/2 sine, 11 msec)
Non-Operating Shock
20g (1/2 sine, 11 msec)
Operating Vibration
0.003 in. p-p, 10-57 Hz sine,
0.5g peak, 57-640 Hz sine
Non-Operating Vibration
0.006 in. p-p, 10-57 Hz sine,
1.0g peak, 57-640 Hz sine
Physical
Overall Dimensions
(W x H x D)
17.64 in. x 15.41 in. x 4.05 in.
(448.1 mm x 391.4 mm x 102.9 mm)
Net Weight
14.0 lb. (6.4 kg)
Certifications -
Agency Approvals
UL 1950 Listed, C-UL 1950 Listed
LVD (73/23/EEC)
EN 60950 (per UL 1950 3
rd
ed. without D3 dev.)
EMC (89/336/EEC)
Emissions
Immunity
EN 50081-2
EN 50082-2
Australian C-Tick
FCC Class A