Publication 6185-UM001B-EN-P

2. Obtain 75 ohm coaxial cables fitted with BNC connectors. Make

sure the cables are of equal length and are of adequate length to
provide connections from the video source to the adapter cable.

3. Plug the BNC coax cables into the BNC receptacles on the adapter

cable.

Note:

The BNC cables are color coordinated for the red,
green, and blue connectors. The horizontal and vertical
sync connectors are typically gray and black. The
letters H (horizontal sync) and V (vertical sync) are
embossed on the plastic covering of the appropriate
connector.

4. Connect the other end of the coax connectors to the corresponding

output of the video source. For example, connect the red output
cable from the host to the red input connector from the monitor.

Connecting the Optional Touchscreen Interface
(All Models)

An optional serial touchscreen interface connection to the host can be
made through an RS-232 DE-9 (female) D-shell connector located on the
side panel.

The optional touchscreen provides a high-resolution touch input system.
Driver software included with the package allows the touchscreen to
function with many popular DOS and Windows

®

-based industrial

applications as a pointing device (mouse).

Note:

Refer to the manual included with the touchscreen option
and Appendix A of this manual (Page 54) for additional
details on the installation and operation of the touchscreen.

To connect the touchscreen:
1. For units with the touchscreen option, make sure you have one of the

optional serial cables.

2. Connect one end of the touchscreen serial cable to the T/S port

connector on the side of the monitor.

3. Connect the other end to any communications port on the host

computer.