beautypg.com

Connecting dc power (dc power option) – Rockwell Automation 6185-V Industrial 18.1 Inch Flat Panel Monitor User Manual User Manual

Page 32

background image

32

Industrial 18.1" Flat Panel Monitor

Publication 6185-UM001B-EN-P

Connecting DC Power (DC Power Option)

All models of the 6185 Flat Panel Monitor can be run with direct current.
Table C below lists the power requirements for each model.

Table C
DC Power Requirements for Model 6185 18" Flat Panel Monitors

Model

Power Requirement

Panel mount (6185-D)

Rack mount (6185-N)

24 VDC (18-32 VDC)

Versa mount (6185-V)

12 VDC (±5%)

Note:

The Versa mount unit can be directly connected to a power
source using a cable with a locking DIN connector provided
with your equipment.

To connect DC power to the panel mount (6185-D) or rack mount (6185-N)

monitor:
1. Turn off the main switch or breaker.

2. Use the ground terminal on the monitor below the power connector

to establish a chassis-to-earth ground connection. Secure one end of
a ground strap to the ground terminal. Connect the other end of the
ground strap to a good earth ground.

The ground terminal is an M5 screw.

ATTENTION: Chassis ground must be connected for
safe operation of the monitor. The DC screw terminals on
the monitor have a chassis ground pin. However, some
DC sources may not provide a proper ground path. If you
fail to ground the monitor properly, the setup may result
in personal injury from electrical shock or damage to the
equipment.

ATTENTION: EXPLOSION HAZARD! – Do not
disconnect equipment unless power has been switched off
or the area is known to be non-hazardous.