Parameter group listing, Devicelogix™ group, Table 3.1 parameter group listing – Rockwell Automation 284D ArmorStart - Safety Version - User Manual User Manual
Page 44
![background image](/manuals/578099/44/background.png)
3-2
Bulletin 280/281 Programmable Parameters
Parameter Group Listing
The Bulletin 280/281 ArmorStart contains eight parameter groups.
The parameters shown in the DeviceLogix, DeviceNet, Starter
Protection, User I/O, Misc. Parameter, ZIP Parameters, Starter
Display and Starter Setup, are discussed in this chapter.
Table 3.1
Parameter Group Listing
DeviceLogix™ Group
DeviceLogix
DeviceNet
Starter
Protection
User I/O
Misc.
ZIP Parameters
Starter Display
Starter Setup
1 Hdw Inputs
10 Autobaud Enable
22 Breaker Type
30 Off-to-On Delay
45 Keypad Mode
67 AutoRun Zip
101 Phase A Current
106 FLA Setting
2 Network Inputs
11 Consumed IO Assy
23 PrFltResetMode
31 On-to-Off Delay
46 Keypad Disable
68 Zone Produced EPR 102 Phase B Current
107 Overload Class
3 Network Outputs
12 Produced IO Assy
24 Pr Fault Enable
32 In Sink/Source
47 Set To Defaults
69 Zone Produced PIT
103 Phase C Current
108 OL Reset Level
4 Trip Status
13 Prod Assy Word 0
25 Pr Fault Reset
33 OutA Pr FltState
56 Base Enclosure
70 Zone #1 MacId
104 Average Current
5 Starter Status
14 Prod Assy Word 1
26 StrtrDN FltState
34 OutA Pr FltValue
57 Base Option
71 Zone #2 MacId
105% Therm Utilized
6 DNet Status
15 Prod Assy Word 2
27 StrtrDN FltValue
35 OutA DN FltState
58 Wiring Option
72 Zone #3 MacId
7 Starter Command
16 Prod Assy Word 3
28 StrtrDN IdlState
36 OutA DN FltValue
59 Starter Enclosure
73 Zone #4 MacId
8 Network Override
17 Consumed IO Size
29 StrtrDN IdlValue
37 OutA DN IdlState
60 Starter Options
74 Zone #1 Health
9 Comm Override
18 Produced IO Size
61 Last PR Fault
38 OutA DN IdlValue
75 Zone #2 Health
19 Starter COS Mask
62 Warning Status
39 OutB Pr FltState
76 Zone #3 Health
20 Net Out COS Mask
40 OutB Pr FltValue
77 Zone #4 Health
21 DNet Voltage
41 OutB DN FltState
78 Zone #1 Mask
42 OutB DN FltValue
79 Zone #2 Mask
43 OutB DN IdlState
80 Zone #3 Mask
44 OutB DN IdlValue
81 Zone #4 Mask
82 Zone #1 Offset
83 Zone #2 Offset
84 Zone #3 Offset
85 Zone #4 Offset
86 Zone #1 EPR
87 Zone #2 EPR
88 Zone #3 EPR
89 Zone #4 EPR
90 Zone #1 Control
91 Zone #2 Control
92 Zone #3 Control
93 Zone #4 Control
94 Zone #1 Key
95 Zone #2 Key
96 Zone #3 Key
97 Zone #4 Key
98 Device Value Key
99 Zone Ctrl Enable
Hdw Inputs
This parameter provides status of
hardware inputs
Parameter Number
1
Access Rule
GET
Data Type
WORD
Group
DeviceLogix
Units
—
Minimum Value
0
Maximum Value
15
Default Value
0