Rockwell Automation 284D ArmorStart - Safety Version - User Manual User Manual
Page 264
![background image](/manuals/578099/264/background.png)
C-16
Bulletin 284 CIP Information
Instances 5…6 will be available Group 3 explicit message
connections that are allocated through the UCMM. The following
attributes are supported
Table C.37 Connection Object Instance 5...7 Attributes:
Attribute
ID
Access
Rule
Name
Data
Type
Value
1
Get
State
USINT
0 = non-existent
1 = configuring
3 = established
4 = timed out
2
Get
Instance Type
USINT
0 = Explicit
Message
3
Get
Transport Class Trigger
USINT
0x83 — Server,
Transport Class 3
4
Get
Produced Connection ID
UINT
Depends on message
group and Message ID
5
Get
Consumed Connection ID
UINT
Depends on message
group and Message ID
6
Get
Initial Comm Characteristics
USINT
0x33 (Group 3)
7
Get
Produced Connection Size
UINT
0
8
Get
Consumed Connection Size
UINT
9
Get/Set
Expected Packet Rate
UINT
in milliseconds
12
Get
Watchdog Action
USINT
01 = auto delete
03 = deferred delete
13
Get
Produced Connection Path
Length
UINT
0
14
Get
Produced Connection Path
Empty
15
Get
Consumed Connection Path
Length
UINT
0
16
Get
Consumed Connection Path
Empty