Table 11.6 Miscellaneous Situations
Display
Possible Cause
Possible Solutions
Motor current and voltage fluctuates with
steady load
Motor
Erratic load
Verify type of motor as a standard squirrel cage
induction motor
Check load conditions
Erratic operation
Loose connections
Shut off all power to controller and check for loose
connections
Accelerates too fast
Starting time
Initial torque
Current limit setting
Kickstart
Increase starting time
Lower initial torque setting
Decrease current limit setting
Lower kickstart time or turn off
Accelerates too slow
Starting time
Initial torque
Current limit setting
Kickstart
Decrease starting time
Increase initial torque setting
Increase current limit setting
Increase kickstart time or turn off
Motor stops too quickly with Soft Stop
Time setting
Verify the programmed stopping time and correct it
or increase
Motor stops too slowly with Soft Stop
Stopping time setting
Misapplication
Verify the programmed stopping time and correct if
necessary
The Soft Stop is intended to extend the stopping
time for loads that stop suddenly when power is