Rockwell Automation 21G PowerFlex 750-Series AC Drives Reference Manual User Manual

Page 173

background image

Rockwell Automation Publication 750-RM001F-EN-P - February 2012

173

Parameter Data

Appendix B

Fil

e

Gr

ou

p

No.

Display Name
Full Name
Description

Values

Re

ad

-Write

Da

ta T

ype

Sa

fe

Speed Mon

it

or

Do

or C

on

tr

ol

57

Door Out Type
Door Output Type
Defines the lock and unlock state for door control output (DC_Out).
When Door Out Type equals power to release, DC_Out is OFF in the lock state and ON in
the unlock state.
When Door Out Type equals power to lock, DC_Out is ON in the lock state and OFF in the
unlock state.
The first and middle units of a multi-axis system must be configured as cascading (2).

Default:
Options:

0 = “Pwr to Rel”
0 = “Pwr to Rel”
1 = “Pwr to Lock”
2 = “2 Ch Sourcing”

RW 8-bit

Integer

58

DM Input
Door Monitor Input
Configuration for the Door Monitor input (DM_In).
“2NC” (1) – Dual-channel equivalent
“2NC 3s” (2) – Dual-channel equivalent 3 s
“1NC+1NO” (3) – Dual-channel complementary
“1NC+1NO 3s” (4) – Dual-channel complementary 3 s
“2 OSSD 3s” (5) – Dual-channel SS equivalent 3 s
“1NC” (6) – Single channel equivalent

Default:
Options:

0 = “Not Used”
0 = “Not Used”
1 = “2NC”
2 = “2NC 3s”
3 = “1NC+1NO”
4 = “1NC+1NO 3s”
5 = “2 OSSD 3s”
6 = “1NC”

RW 8-bit

Integer

59

Lock Mon Enable
Lock Monitor Enable
Lock Monitoring can only be enabled when the speed monitoring safety option is a
single unit or as the first unit in a multi-axis system (P20 [Cascaded Config] = 0 or 1).

Default:
Options:

0 = “Disable”
0 = “Disable”
1 = “Enable”

RW 8-bit

Integer

60

Lock Mon Input
Lock Monitor Input
Configuration for the Lock Monitor input (LM_In).
“2NC” (1) – Dual-channel equivalent
“2NC 3s” (2) – Dual-channel equivalent 3 s
“1NC+1NO” (3) – Dual-channel complementary
“1NC+1NO 3s” (4) – Dual-channel complementary 3 s
“2 OSSD 3s” (5) – Dual-channel SS equivalent
“1NC” (6) – Single channel equivalent

Default:
Options:

0 = “Not Used”
0 = “Not Used”
1 = “2NC”
2 = “2NC 3s”
3 = “1NC+1NO”
4 = “1NC+1NO 3s”
5 = “2 OSSD 3s”
6 = “1NC”

RW 8-bit

Integer

74

Door Out Mode
Defines whether the DC_Out output is pulse-tested.
If pulse-testing is turned off for any output, the SIL, Category, and PL rating is reduced
for the entire safety system.

Default:
Options:

0 = “Pulse Test”
0 = “Pulse Test”
1 = “No Pulse Tst”

RW 8-bit

Integer