beautypg.com

Appendix, Code table – Lenze LDECBBF1xxxxxxHx User Manual

Page 91

background image

Appendix

Code table

10

l

91

LDEDS−CCU210B EN 4.0

Description

Possible settings

Code

Selection

Lenze

Byte

<

ñò

No.

C0161

R

4

No. of the current error message

0

255

C0167
[PWD]

RW

4

0

Fault memory (C0168, C0169) and
limit value memory (C0183−C0196)
are deleted if:

l

the service password has been
entered in C0007 and

l

C0167 is set to "1".

Only the limit value memory
(C0183−C0196) is deleted if:

l

the user password has been
entered in C0007 and

l

C0167 is set to "1".

0

Action executed

1

Delete fault memory and/or limit
value memory

C0168

Fault memory: no. of the 10 faults
that occurred last

^ 81

1

R

INT

4

1

255 Error 1 (latest)

2

Error 2

3

Error 3

4

Error 4

5

Error 5

6

Error 6

7

Error 7

8

Error 8

9

Error 9

10

Error 10 (first)

C0169

Error memory: times of the 10
errors that occurred last

^ 81

1

R

INT

4

0

{min}

7884000 Time error 1 (latest)

2

Time error 2

3

Time error 3

4

Time error 4

5

Time error 5

6

Time error 6

7

Time error 7

8

Time error 8

9

Time error 9

10

Time error 10 (first)

C0179

R

INT

4

Power−on time

^ 75

0

{min}

7884000

C0180

R

1

Seconds counter

^ 75

0

{s}

59

C0183

Limit values of the DC−bus voltage

^ 75

1

R

4

0

{V}

1000 Minimum

2

Maximum

C0184

Limit values of the current value

^ 75

1

R

INT

4

0

{A}

20.0 Reserved

2

Maximum