3 assignment logic, Assignment logic, Function library – Lenze LDECBBF1xxxxxxHx User Manual

Page 46: Digital input signals assignment logic

background image

Function library

Digital input signals
Assignment logic

8

l

46

LDEDS−CCU210B EN 4.0

8.3.3

Assignment logic

In the assignment logic (C0410) you assign digital signal sources, like for instance digital
inputs or linkage results, to the internal control functions. By this, you define the desired
control functions and responses to specific events.

Codes for parameter setting

Code

Possible settings

Description

No.

ñò

< Byte Lenze

Selection

C0410

Linking digital input signals to an
internal device function ...

^ 46

1 RW

EXT

4

0

Not assigned

... Motor V1 (incl. brake)

2

0

Not assigned

... Motor V2 (incl. brake)

3

0

Not assigned

... Motor V3 (incl. brake)

4

0

Not assigned

... Motor V4 (incl. brake)

5

0

Not assigned

... Motor V5 (incl. brake)

6

0

Not assigned

... Motor V6 (incl. brake)

7

0

Not assigned

... Motor V7 (incl. brake)

8

0

Not assigned

... Motor V8 (incl. brake)

9

0

Not assigned

... CW/CCW rotation of motor

l

CW rotation = LOW

l

CCW rotation = HIGH

10

0

Not assigned

Reserved

11

0

Not assigned

... Set fault

12

0

Not assigned

...Acknowledge fault

13

0

Not assigned

... Frequency inverter: change over
parameter set

l

Parameter set 1 = LOW

l

Parameter set 2 = HIGH

14

0

Not assigned

... DC−injection braking

15

0

Not assigned

... Open brake

16

0

Not assigned

... Stop1

17

0

Not assigned

... Stop2

18

0

Not assigned

... Stop3

19

0

Not assigned

... Stop4

20

0

Not assigned

... Frequency limitation 1

21

0

Not assigned

... Frequency limitation 2

22

0

Not assigned

... Frequency limitation 3

23

0

Not assigned

... Frequency limitation 4

24

0

Not assigned

... SensoPart: change over
parameter set

l

Parameter set 1 = LOW

l

Parameter set 2 = HIGH

25

0

Not assigned

... Deactivate control