Ethercat: error: lenze setting loaded [0x00c86420, Ethercat: quit 'operational' state [0x00c88131, Ethercat: sync loss detected with standard device – Lenze E94AYCET User Manual
Page 93: 0x00c88132, 0x00c86420, 0x00c88131, 12 error messages
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17
93
12
Error messages
12.2
Possible causes and remedies
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
EtherCAT: Error: Lenze setting loaded [0x00c86420]
EtherCAT: Quit 'Operational' state [0x00c88131]
EtherCAT: Sync loss detected with standard device [0x00c88132]
Response (Lenze setting printed in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
Access via standard device to parameter set in the
memory module was not successful.
Repeat download of the application (including module).
Response (Lenze setting printed in bold)
Setting:
/
( Configurable response)
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
The EtherCAT data exchange was stopped in the
"Operational" state.
See also chapter "
• Check cables and terminals.
• The master has to reset the node to the "Operational"
status. (If required, check a pending emergency
message first).
Response (Lenze setting printed in bold)
Setting: not possible
None System fault Fault Trouble Quick stop by trouble Warning locked Warning Information
Cause
Remedy
• The cycle time settings are faulty.
• The task time setting of a linked PLC program is faulty.
• EtherCAT master / DC master settings are incorrect.
• The sync source setting is faulty.
• Check the cycle times.
• Check the task time of a linked PLC program.
• Check the EtherCAT master / DC master settings.
• Check the settings of the standard device in
(selection of the sync source).