C14853 | all words from standard device, C14861 | bus status, C14864 | active station address – Lenze E94AYCET User Manual
Page 126: C14867 | display: most recent emergency data, C14861, C14864, C14867, 13 parameter reference
13
Parameter reference
13.3
Parameters of the communication module for slot MXI2
126
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14853
C14861
C14864
C14867
Parameter | Name:
C14853 | All words from standard device
Data type: UNSIGNED_16
Index: 9722 = 0x25FA
Display of the process data words (subcodes 1 ... 32) which are transferred from the standard device to the
communication module.
Display area
(min. value | unit | max. value)
0
65535
Subcodes
Info
C14853/1
...
C14853/32
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14861 | Bus status
Data type: UNSIGNED_16
Index: 9714 = 0x25F2
Display of the current bus status
Selection list
(read only)
Info
0 Nonexistent
No online value available (communication module is
offline).
1 Init
2 Pre-operational
3 Bootstrap
Is not supported.
4 Safe-operational
8 Operational
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14864 | Active station address
Data type: UNSIGNED_16
Index: 9711 = 0x25EF
Display of the station address allocated by the master
Display area
(min. value | unit | max. value)
0
65535
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14867 | Display: Most recent emergency data
Data type: OCTET_STRING
Index: 9708 = 0x25EC
Display of the emergency data last sent by the drive (string with a length of 8 bytes).
Emergency requests / Emergency messages ( 89)
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT