beautypg.com

2 operation at rated mains voltage 500 v, Operation at rated mains voltage 500 v, Braking operation – Lenze 8400 BaseLine Manual User Manual

Page 97: 790 v, adjustable

background image

Braking operation

Braking operation with external brake resistor

Operation at rated mains voltage 500 V

8

97

EDS84ABD302 EN 4.0

8.3.2

Operation at rated mains voltage 500 V

Switching threshold V

BRmax

: 790 V, adjustable

R

Bmin

[Ω]

I

BRmax

[A]

P

BRmax

[kW]

I

BRd

[A]

P

Bd

[kW]

t

Z

[s]

t

on

[s]

t

fp

[s]

Type
E84AVBxx3714

390

2.0

1.6

2.0

1.6

-

-

E84AVBxx5514

390

2.0

1.6

2.0

1.6

-

-

E84AVBxx7514

390

2.0

1.6

2.0

1.6

-

-

E84AVBxx1124

180

4.4

3.5

4.4

3.5

-

-

E84AVBxx1524

180

4.4

3.5

4.4

3.5

-

-

E84AVBxx2224

150

5.3

4.2

5.3

4.2

-

-

E84AVBxx3024

100

7.9

6.2

7.9

6.2

-

-

R

Bmin

Minimum brake resistance, nominal value ±10 %

I

BRmax

Peak current

P

BRmax

Peak braking power

I

BRd

Continuous current RMS - important for cable dimensioning

P

Bd

Continuous braking power

t

Z

Cycle time, periodic load change with running time and recovery time

t

on

Running time in a cycle without reducing the scanning ratio (∞= no time limit)

t

Z

- t

on

Recovery time

t

fp

Maximum running time without initial load and observing the recovery time