EDS84ABD302 EN 4.0

Fuses and cable cross-sections

Operation without external mains choke/mains filter
Type

Installation according to EN 60204-1

1)

Installation according

to UL

2)

FI

3)

c

d

L1, L2, L3 - Laying system

e

L1, L2, L3

B2

C

F

[A]

[A]

[mm

2

]

[mm

2

]

[mm

2

]

[A]

[AWG]

[mA]

E84AVBxx3714

C6

6

1.5

-

-

10

14

30

E84AVBxx5514

C6

6

1.5

-

-

10

14

E84AVBxx7514

C6

6

1.5

-

-

10

14

E84AVBxx1124

C10

10

1.5

-

-

10

14

E84AVBxx1524

C10

10

1.5

-

-

10

14

E84AVBxx2224

C10

10

1.5

-

-

10

14

E84AVBxx3024

C16

16

1.5

-

-

12

14

1)

These values are recommendations only. Other dimensioning values/laying systems are possible (e.g. according to

VDE 0298-4). The cable cross-sections apply under the following conditions: Use of PVC-insulated copper cables,

conductor temperature < 70 °C, ambient temperature < 45°C, no bundling of cables or cores, three loaded cores.

2)

Use UL-approved cables, fuses and fuse holders only.

UL fuse: voltage ≥ 500 V, tripping characteristic ”H”, ”K5” or ”CC”. The cable cross-sections apply under the following

conditions: conductor temperature < 75 °C, ambient temperature < 45°C.

3)

Universal-current sensitive earth-leakage circuit breaker, short-time delay

If cables are longer than 50 m, the protective circuit-breaker may respond, depending on the cable type and

switching frequency.

c

Circuit breaker

d

Fuse

e

Fuse

Observe national and regional regulations

Operation with external mains choke/mains filter
Type

Installation according to EN 60204-1

1)

Installation according

to UL

2)

FI

3)

c

d

L1, L2, L3 - Laying system

e

L1, L2, L3

B2

C

F

[A]

[A]

[mm

2

]

[mm

2

]

[mm

2

]

[A]

[AWG]

[mA]

E84AVBxx3714

C6

6

1.5

-

-

10

14

30

E84AVBxx5514

C6

6

1.5

-

-

10

14

E84AVBxx7514

C6

6

1.5

-

-

10

14

E84AVBxx1124

C6

6

1.5

-

-

10

14

E84AVBxx1524

C10

10

1.5

-

-

10

14

E84AVBxx2224

C10

10

1.5

-

-

10

14

E84AVBxx3024

C16

16

1.5

-

-

12

14

1)

These values are recommendations only. Other dimensioning values/laying systems are possible (e.g. according to

VDE 0298-4). The cable cross-sections apply under the following conditions: Use of PVC-insulated copper cables,

conductor temperature < 70 °C, ambient temperature < 45°C, no bundling of cables or cores, three loaded cores.

2)

Use UL-approved cables, fuses and fuse holders only.

UL fuse: voltage ≥ 500 V, tripping characteristic ”H”, ”K5” or ”CC”. The cable cross-sections apply under the following

conditions: conductor temperature < 75 °C, ambient temperature < 45°C.

3)

Universal-current sensitive earth-leakage circuit breaker, short-time delay

If cables are longer than 50 m, the protective circuit-breaker may respond, depending on the cable type and

switching frequency.

c

Circuit breaker

d

Fuse

e

Fuse

Observe national and regional regulations