beautypg.com

2 rated data, 1 overview, Overview – Lenze 8400 BaseLine Manual User Manual

Page 24: Technical data, Rated data overview, 2 rated data 4.2.1 overview input data

background image

Technical data

Rated data

Overview

4

24

EDS84ABD302 EN 4.0

4.2

Rated data

4.2.1

Overview

Input data

Basis of the data

Mains

Voltage

U

LN

[V]

Voltage range

U

LN

[V]

Frequency range

f [Hz]

1/N/PE AC

230

180 - 0 % ... 264 + 0 %

45 - 0 % ... 65 + 0 %

3/PE AC

400

320 - 0 % ... 440 + 0 %

45 - 0 % ... 65 + 0 %

3/PE AC

500

400 - 0 % ... 550 + 0 %

45 - 0 % ... 65 + 0 %

Voltage

Frequency

Current [A]

Number of

phases

Type

[V]

[Hz]

max. +45 °C

c

max. +55 °C

c

E84AVBxx2512

230

50/60

3.4

2.6

1

E84AVBxx3712

230

50/60

5.1

3.8

1

E84AVBxx5512

230

50/60

6.7

5.0

1

E84AVBxx7512

230

50/60

8.8

6.6

1

E84AVBxx1122

230

50/60

12

9.0

1

E84AVBxx1522

230

50/60

13.7

10.3

1

E84AVBxx2222

230

50/60

22.0

18.4

1

E84AVBxx3714

400/500

50/60

1.8/1.5

1.4/1.1

3

E84AVBxx5514

400/500

50/60

2.3/2.0

1.7/1.5

3

E84AVBxx7514

400/500

50/60

3.2/2.7

2.4/2.0

3

E84AVBxx1124

400/500

50/60

4.2/3.6

3.2/2.7

3

E84AVBxx1524

400/500

50/60

4.7/4.1

3.5/3.1

3

E84AVBxx2224

400/500

50/60

6.2/5.4

4.7/4.1

3

E84AVBxx3024

400/500

50/60

10.2/7.8

7.7/5.9

3

c

Ambient temperature in the control cabinet, switching frequency 2 and 4 kHz, operation without mains choke