Technical data

Control terminals

Digital inputs

4

42

EDS84ABD302 EN 4.0

4.5.3

Digital inputs

Labelling

Features

Rated value

DI1, DI2

Digital input 1/2

according to IEC61131-2, type 1

DI3, DI4

Digital input 3/4

according to IEC61131-2, type 1

RFR

Controller inhibit

according to IEC61131-2, type 1

Input resistance

3.3 kΩ (2.0 kΩ ... 5.0 kΩ)

Electric strength of external voltage

+10 ... +30 V DC, permanent

Level

LOW = 0 ... +2.5 V DC

HIGH = +10 ... 30 V DC

Cycle time

1 ms

Isolation

47

4.5.4

Digital outputs

Labelling

Features

Rated value

DO1

GND

Digital output

In accordance with IEC61131-2, type

1, max. 50 mA

External-voltage protected

Up to +30 V

Integrated polarity reversal protection

diode for switching inductive loads

Isolation

47

Level

LOW < +5 V

HIGH > +15 V

Behaviour during overload

Reduced voltage or periodical

switch-off/on

Behaviour during reset and switch-on

Outputs are switched off (LOW)

Cycle time

1 ms

4.5.5

Relay output connection

Labelling

Description/features

Rated value

COM

Central contact of relay

AC 250 V, 3 A

DC 24 V, 2 A

DC 240 V, 0.22 A

NO

NO contact (normally open)

Note!

ƒ

The minimum load of the switching contacts should not fall below

12 V and 5 mA.

ƒ

To avoid premature contact wear caused by erosion, a protective circuit

(free-wheeling diode, varistor, RC filter or RCD filter) is required, especially in

case of inductive load.