Commissioning

Before switching on

7

82

EDS84ABD302 EN 4.0

7

Commissioning

Note!

Please observe the general safety instructions and the residual hazards in

chapter 2.1 and 2.3.

7.1

Before switching on

Note!

ƒ

Comply with the corresponding switch-on sequence.

ƒ

In case of faults during commissioning please use:

– the online help in the »Engineer«

– the software manual 8400 BaseLine D

– the software manual 8400 BaseLine C

To prevent injury to persons or damage to material assets, check ...
... before connecting the mains voltage:

ƒ

Wiring for completeness, short circuit, and earth fault

ƒ

The ”EMERGENCY STOP” function of the entire system

ƒ

The motor circuit configuration (star/delta) must be adapted to the output voltage

of the controller

ƒ

The in-phase connection of the motor (rotational direction)

... the most important drive parameter settings before the controller is enabled:

ƒ

Is the V/f rated frequency adapted to the motor circuit configuration?

ƒ

Are the drive parameters relevant for your application set correctly?

ƒ

Is the configuration of the analog input and the digital inputs adapted to wiring?