beautypg.com

1 device overload for 15-s cycle, Device overload for 15-s cycle, Technical data – Lenze 8400 BaseLine Manual User Manual

Page 37: Operation at rated mains voltage 400 v, Operation at rated mains voltage 500 v

background image

Technical data

Overcurrent operation

Device overload for 15-s cycle

4

37

EDS84ABD302 EN 4.0

4.3.1

Device overload for 15-s cycle

Operation at rated mains voltage 230 V

Type

I

amax

/I

aN8

[%] in 15-s cycle c

f = 2 kHz

f = 4 kHz

f = 8 kHz

f = 16 kHz

E84AVBxx2512

200

75

200

75

200

75

133

50

E84AVBxx3712
E84AVBxx5512
E84AVBxx7512
E84AVBxx1122
E84AVBxx1522
E84AVBxx2222

Operation at rated mains voltage 400 V

Type

I

amax

/I

aN8

[%] in 15-s cycle c

f = 2 kHz

f = 4 kHz

f = 8 kHz

f = 16 kHz

E84AVBxx3714

175

80

175

80

175

80

133

50

E84AVBxx5514
E84AVBxx7514
E84AVBxx1124
E84AVBxx1524
E84AVBxx2224
E84AVBxx3024

170

80

170

80

170

80

133

50

Operation at rated mains voltage 500 V

Type

I

amax

/I

aN8

[%] in 15-s cycle c

f = 2 kHz

f = 4 kHz

f = 8 kHz

f = 16 kHz

E84AVBxx3714

200

75

200

75

200

75

133

50

E84AVBxx5514
E84AVBxx7514
E84AVBxx1124
E84AVBxx1524
E84AVBxx2224
E84AVBxx3024