beautypg.com

Technical data, General data and operating conditions – Lenze 8400 BaseLine Manual User Manual

Page 23

background image

Technical data

General data and operating conditions

4

23

EDS84ABD302 EN 4.0

Control
Control method

VFCplus:

z

V/Hz loop (linear or square-law)

SLVC:

z

Sensorless vector control (speed)

Switching frequency

2 kHz, 4 kHz, 8 kHz, 16 kHz,

Optionally noise optimised or power loss optimised

Torque behaviour

Maximum torque

1.5 x M

N

for 60 s

1.8 x M

N

for 3 s

if rated motor power = rated controller power

Setting range

1 : 10

In SLVC:

z

in the speed range 3 ... 50 Hz

In V/f:

z

in the speed range 10 ... 50 Hz

Sensorless vector control (speed)

Minimum output

frequency

0.5 Hz (0 ... M

N

)

Setting range

1 : 10

referring to 50 Hz and M

N

Accuracy

±

0.5 %

in the speed range 3 ... 50 Hz

Smooth running

±

0.1 Hz

Output frequency

Range

-300 Hz ... +300 Hz

Absolute resolution

0.2 Hz

Standardised

resolution

Parameter data: 0.01 %, process data: 0.006 % (= 2

14

)

Digital setpoint selection

Accuracy

±

0.01 %

Analog setpoint selection

Accuracy

±

0.5 %

referring to final value