beautypg.com

Technical data, Rated data operation at rated mains voltage 500 v, 790 v, adjustable – Lenze 8400 BaseLine Manual User Manual

Page 34

background image

Technical data

Rated data

Operation at rated mains voltage 500 V

4

34

EDS84ABD302 EN 4.0

Output currents [A] at switching frequency

2 kHz

4 kHz

8 kHz

16 kHz

Type

I

aN2

I

aM2

I

aN4

I

aM4

I

aN8

I

aM8

I

aN16

I

aM16

E84AVBxx3714

1.0

2.0

1.0

2.0

1.0

2.0

0.7

1.4

E84AVBxx5514

1.4

2.8

1.4

2.8

1.4

2.8

0.9

1.8

E84AVBxx7514

1.9

3.8

1.9

3.8

1.9

3.8

1.3

2.6

E84AVBxx1124

2.6

5.2

2.6

5.2

2.6

5.2

1.7

3.4

E84AVBxx1524

3.1

6.2

3.1

6.2

3.1

6.2

2.1

4.2

E84AVBxx2224

4.5

9.0

4.5

9.0

4.5

9.0

3.0

6.0

E84AVBxx3024

5.8

11.6

5.8

11.6

5.8

11.6

3.9

7.8

I

aNx

Rated value - continuous output current

I

aMx

Maximum output current (overload current)

z

Periodic load change of 3 s with I

aMx

and recovery time of 12 s with 75 % I

aNx

z

Can be achieved with the setting ”x kHz fixed/...” in C00018

Switching

frequency

When the maximum heatsink temperature is reached, the switching frequency

is reduced to 4 kHz.
With the setting ”x kHz var./...” in C00018, the switching frequency is reduced

dynamically.

z

At 16 kHz and Ia > 100 % x IaN8 to 8 kHz

z

At 8 kHz and Ia > 150 % x IaN8 to 4 kHz

Rated data for internal brake chopper
Switching threshold V

BRmax

: 790 V, adjustable

R

Bmin

[Ω]

I

BRmax

[A]

P

BRmax

[kW]

I

BRd

[A]

P

Bd

[kW]

t

Z

[s]

t

on

[s]

t

fp

[s]

Type
E84AVBxx3714

390

2.0

1.6

2.0

1.6

-

-

E84AVBxx5514

390

2.0

1.6

2.0

1.6

-

-

E84AVBxx7514

390

2.0

1.6

2.0

1.6

-

-

E84AVBxx1124

180

4.4

3.5

4.4

3.5

-

-

E84AVBxx1524

180

4.4

3.5

4.4

3.5

-

-

E84AVBxx2224

150

5.3

4.2

5.3

4.2

-

-

E84AVBxx3024

100

7.9

6.2

7.9

6.2

-

-

R

Bmin

Minimum brake resistance, nominal value ±10 %

I

BRmax

Peak current

P

BRmax

Peak braking power

I

BRd

Continuous current RMS - important for cable dimensioning

P

Bd

Continuous braking power

t

Z

Cycle time, periodic load change with running time and recovery time

t

on

Running time in a cycle without reducing the scanning ratio (∞= no time limit)

t

Z

- t

on

Recovery time

t

fp

Maximum running time without initial load and observing the recovery time