beautypg.com

Electrical installation, Control terminals digital inputs and outputs, Example circuit – Lenze 8400 BaseLine Manual User Manual

Page 79

background image

Electrical installation

Control terminals

Digital inputs and outputs

6

79

EDS84ABD302 EN 4.0

Example circuit

S1

" I/O Shields

X13

12I

GND

DI2

50

mA

DI1

DI3

DI4

RFR

X4

3.3k

3.3k

3.3k

3.3k

3.3k

12

V

24E

DO1

GND

GND

E84AVBx...

-

+

12I

GND

DI2

50

mA

DI1

DI3

DI4

RFR

X4

3.3k

3.3k

3.3k

3.3k

3.3k

12

V

24E

DO1

GND

GND

E84AVBx...

S1

" I/O Shields

X13

8400BLD015

8400BLD017

12I

GND

DI2

50

mA

DI1

DI3

DI4

RFR

X4

3.3k

3.3k

3.3k

3.3k

3.3k

12

V

24E

DO1

GND

GND

E84AVBx...

DC 24 V

(+15.0 ... +30.0 V)

12I

GND

DI2

50

mA

DI1

DI3

DI4

RFR

X4

3.3k

3.3k

3.3k

3.3k

3.3k

12

V

24E

DO1

GND

GND

E84AVBx...

8400BLD046

8400BLD046

Fig. 6-21

Wiring examples of the digital inputs

Wiring with one or several digital inputs (here: DI1);
option: internal 12 V supply

Wiring one or several digital inputs with external 10 V to 30 V DC supply

Digital output with internal 12 V supply

Digiral output with external 24 V supply

RFR

Input for controller enable; wiring is always required.

X4

Terminal for the analog input and digital inputs and output

X13

Terminal for I/O shields

GND

GND for analog and digital signals

DO1

The digital output is not available for devices with nameplate data

E84AVBDxxxxSX0