EUCHNER AS-i 3.0 Command Interface User Manual
Page 22

AS-i 3.0 Command Interface
Commands of the Command Interface
Subject to reasonable modifications due to technical advances
Id.-No.: 102875 Issue date - 3.12.2007
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16, D-70771 Leinfelden-Echterdingen
Tel. +49/711/7597-0, Fax +49/711/753316
22
It is recommended to start reading the data always using index i
≡ 0. This message
also contains the header. The user data length is therefore reduced by 3 bytes.
Data with length i
≡ 0 can be read successfull only once. Each further read
command with length i
≡ 0 ist quit with an error. Therefore further read pro-
cess (sections) must be carried out with i >0!
Response buffer
Byte
2
7
2
6
2
5
2
4
2
3
2
2
2
1
2
0
1
command
1
1. FFh signifies transfer still active, FEh signified transfer interrupted with errors. In the correct case the command from
WRITE_ACYC_TRANS is given here.
2
length byt
2
e n (high)
2. Transmit buffer length n
3
length byte n (low)
4
data 0
...
...
n+3
data n-1
For further information
i=0
i=m-2
read section of the string
command
length byte high
length byte low
data 0
data n-1
command
length byte high
length byte low
data 0
data n-1
m - command interface response length