beautypg.com

Default device times, Memory fcb times, Default device times memory fcb times – ETC SmartFade ML v3.0.1 User Manual

Page 76: See “default

background image

68

SmartFade ML v3.0.1 User Manual

Default Device Times

There are two types of default device times.

Move Dark Time = A limiting time that sets a maximum speed for any function, mainly
to keep mechanical noise down. This time is used by Move While Dark prepositioning
in sequence/Stack and Home.

Palette Time = A time used when activating a palette or using Align.

They are both set in the Default Time menu
Menu>Setup>Default times[FCB Times]

Use encoder wheel 2 and 3 to set the times. Exit menu when done.

Memory FCB Times

A memory can have a time for the FCB parameters, that is used (only) when they are

executed with the Bump button in GO mode.

See “Memory Bump Modes” on page 83.

Step 1:

Press EDIT

Step 2:

Press TIME.

Step 3:

Now press a bump button for a memory. The display will change to time setting.

Step 4:

Press EDIT to exit.

Test the FCB time

If you have set this time to a memory with devices and want to try it, press CLEAR 4 times

to clear the output. Set all memory faders to zero. Select all devices and set to HOME. Set

faders to INT ONLY and bring up the fader for the memory. Activate GO mode. Press the

bump button for the memory where you set an FCB time. The device parameters should

change in this time.

Menu choice

Console

Feedback

PAGE

Wheel 1

Select another fader page (or press a bump)

MEMORY

Wheel 2

Select another memory (or press a bump)

FCB TIME

Wheel 3

Set the FCB time for the selected memory