beautypg.com

Power on reset, Label length measurement, Set label length – Dascom 7010 Programmers Manual ZPL User Manual

Page 66

background image

66

Default Value:current minute

f = second

Accepted Values:00 to 59

Default Value:current second

g = format

Accepted Values:

A = a.m.

P = p.m.

M = 24-hour military

Default Value:M

~JR

Power On Reset

Description:

The ~JR command resets all of the printer’s internal software,performs a power-on

self-test(POST),clears the buffer and DRAM,and resets communication parameters and default

values.~JR performs the same function as a manual power-on reset.

Format: ~JR

~JC

Label length measurement

Description:

The ~JC command is used to force a label length measurement.

Format: ~JC

Comments:

In continuous mode, this command does not operate..

~JL

Set Label Length

Description:

This manual is related to the following products: