beautypg.com

Print orientation, Field origin – Dascom 7010 Programmers Manual ZPL User Manual

Page 10

background image

10

B = bottom-up 270 degrees, read from bottom up

Initial Value at Power-up: N

Comments:

If the ^FW command is entered with the r parameter missing, the command is ignored.

^FW only affects the orientation in commands where the rotation parameter has not been specifically

set. If an command has a specific rotation parameter, that is the once that is used.

^PO

Print Orientation

Description:

The ^PO command inverts the label format 180 degrees. In essence, the label is printed upside-down.

If the original label contains commands such as ^LL,^LS the inverted label output will be effected

differently.

Format: ^POa

Parameters:

a = invert label 180 degrees

Accepted Values: N(normal) or I(invert)

Default Value: N

Comments:

If multiple ^PO commands are issued in the same label format, only the last command send to the

printer is used.

Once you issue a ^PO command, the setting is retained until another ^PO command is received or

the printer is powered down.

^FO

Field Origin

Description:

The ^FO command sets a field origin, relative to the label home(^LH) position. ^FO sets the

upper-left corner of the field area by defining points along the x-axis and y-axis independent of the

rotation.

Format: ^FOx,y

Parameters:

x = x-axis location(in dots)