44

・No symbol is printed if total code-words is greater than the product of columns and rows.

・Serialization is not allowed with this bar code.

・The truncation feature can be used in situations where label damage is not likely. The right row

indicators and stop pattern will be reduced to a single module bar width. The difference between a

non-truncated and a truncated bar code is shown in Example2.

^BD

UPS MaxiCode Bar Code

Description:

The ^BD command creates a two-dimensional, optically read(not scanned) code. This symbology

was developed by UPS(United Parcel Service).

The code is generated from the information in the ^FD statement which is described generate an

interpretation line. The ^BY command has no affect on the UPS MaxiCode Bar Code.

Format: ^BDm,n,t

Parameters:

m = mode

Accepted Values:

2 – Structured carrier message: numeric postal code(U.S.)

3 – Structured carrier message: alphanumeric postal code(Non-U.S.)

4 – Standard symbol, secretary

5 – Full EEC

6 – Reader program, secretary

Default Value:2

n = symbol number

Accepted Values: 1 to 8 may be added in a structured document.

Default Value:1

t = total number of symbols

Accepted Values: 1 to 8,representing the total number of symbols in this sequence.

Default Value: 1

Example:

^XA
^FO50,50

^BD^FH^FD001840152382802[]>_1E01_1D961Z00004951_1DUPSN_1D_06X610_1D

159_1D1234567_1D1/1_1D_1DY_1D

634 ALPHA DR_1DPITTSBURCH_1DPA_1E_04^FS

^XZ