beautypg.com

Plessey bar code – Dascom 7010 Programmers Manual ZPL User Manual

Page 28

background image

28

Accepted Values: b, c, d

Default Value: a

l = designates stop character

Accepted Values: b, c, d,

Default Value: a

Example

^BP

Plessey Bar code

Description:

The ^BP command is a pulse-width modulated, continuous, non-self-checking symbology.

Each character in the Plessey bar code is composed of eight elements: four bars and four adjacent

spaces.

・Field data(^FD)is limited to the width (or length, if rotated) of the label.

Format: ^BPo,e,h,f,g

Parameters:

o = orientation

Accepted Values:

N = normal

R = rotated 90 degrees(clockwise)

I = inverted 180 degrees

B = read from bottom up,270 degrees

Default Value: Current ^FW value

e = not care

h = bar code height(in dots)

Accepted Values: 1 to 7999(200dpi) / 1 to 11998(300dpi)

Default Value: Value set by ^BY

f = print interpretation line

Accepted Values: Y(yes) or N(no)

Default Value: Y

^XA^FO100,100^BY3

^BKN,N,150,Y,N,A,B

^FD123^XZ

This manual is related to the following products: