Plessey bar code – Dascom 7010 Programmers Manual ZPL User Manual
Page 28

28
Accepted Values: b, c, d
Default Value: a
l = designates stop character
Accepted Values: b, c, d,
Default Value: a
Example:
^BP
Plessey Bar code
Description:
The ^BP command is a pulse-width modulated, continuous, non-self-checking symbology.
Each character in the Plessey bar code is composed of eight elements: four bars and four adjacent
spaces.
・Field data(^FD)is limited to the width (or length, if rotated) of the label.
Format: ^BPo,e,h,f,g
Parameters:
o = orientation
Accepted Values:
N = normal
R = rotated 90 degrees(clockwise)
I = inverted 180 degrees
B = read from bottom up,270 degrees
Default Value: Current ^FW value
e = not care
h = bar code height(in dots)
Accepted Values: 1 to 7999(200dpi) / 1 to 11998(300dpi)
Default Value: Value set by ^BY
f = print interpretation line
Accepted Values: Y(yes) or N(no)
Default Value: Y
^XA^FO100,100^BY3
^BKN,N,150,Y,N,A,B
^FD123^XZ