beautypg.com

Printer configuration, Field hexadecimal indicator, Print mode – Dascom 7010 Programmers Manual ZPL User Manual

Page 13

background image

13

^FH

Field Hexadecimal Indicator

Description:

The ^FH command allows you to enter the hexadecimal value for any character directly into the ^FD

statement. The ^FH command must precede each ^FD command in which it will be used.

Within the ^FD statement, the HEX indicator must precede each hexadecimal value. The default

hexadecimal indicator is _(underscore).There must be a minimum of two characters designated to

follow the underscore. The a parameter can be added when a different hexadecimal indicator is

needed.

This command can be used with any of the commands that have field data(i.e. ^FD, ^SN(Serialized

Data)).

Valid hexadecimal characters are;

0123456789ABCDEFabcdef

Format: ^FHa

Parameters:

a = hexadecimal indicator

Accepted Values: any character except current format and control prefix(^and ~ by

default).

Default Value:_(underscore)

Example:

^FO100,100^AD^FH^FDTilde _7e used for HEX^FS

Printer Configuration

^MM

Print Mode

Description:

The ^MM command determines the action the printer takes after a label or group of labels has been

printed. There are four different modes of operation:

1.Tear-Off - After printing, the label is advanced so that the web is over the tear bar. Label,

with backing attached, can then be torn off manually.