Dascom 7010 Programmers Manual ZPL User Manual
Page 48

48
36, 40, 44, 48, 52, 64, 72, 80, 88, 96, 104, 120, 132, 144).
Moreover, when this value is set as 0, columns is calculated automatically.
The symbol will be sized to a square if the rows and columns do not match.
If the rows and columns value less than 9 but not 0, or if the data is too large for the
forced size, no symbol will print.
f = format ID(0 to 6) – not used with quality set at 200
Accepted Values:
0 = Automatically choose the encodation scheme based on the characters to be
encoded.
1 = Field data is numeric + space(0..9,’ ‘)
2 = Field data is upper-case alphanumeric + space(A..Z,’ ‘)
3 = Field data is uppercase alphanumeric + space, period, comma, dash, and
slash(0..9,A..Z,”.-/”)
4 = Field data is upper-case alphanumeric + space(0..9,A..Z,’ ’)
5 = Field data is full 128 ASCII 7-bit set
6 = Field data is full 256 ISO 8-bit set
Default Values: 6
g = not care
ECC
Level
ID=1
ID=2
ID=3
ID=4
ID=5
ID=6
0 620 452 394 413 310 271
50 457 333 291 305 228 200
80 401 292 255 267 200 175
100 299 218 190 199 149 131
140
144
105 91 96 72 63
Field Data(^FD) for ^BX
Quality 000 to 140
・Other characters in the control character range can only be inserted by using ^FH.
Excess field data will cause no symbol to be printed. The field data must
correspond to a user-specified format ID or no symbol will be printed.
・The maximum field sizes for quality “0” to “140” symbols are shown in the
following table:
Quality 200
Maximum Field Sizes