Media type, Set units of measurement – Dascom 7010 Programmers Manual ZPL User Manual
Page 15

15
Accepted Values:
N = continuous media
Y = non-continuous media
W = non-continuous media web sensing
M = non-continuous media mark sensing
Comments:
If the parameter is missing or invalid, the command will be ignored.
^MT
Media Type
Description:
The ^MT command selects the type of media being used in the printer. There are two choices for this
command;
1.Thermal Transfer Media-This media uses a high carbon black or colored ribbon. The ink
on the ribbon is bonded to the media.
2.Direct Thermal Media-The media is heat sensitive and requires no ribbon.
Format: ^MTa
Parameters:
a = media type used
Accepted Values:
T = thermal transfer media
D = direct thermal media
Comments:
If the parameter is missing or invalid, the command will be ignored.
^MU
Set Units of Measurement
Description:
This command sets the printer units of measurement. The ^MU command works on a field-by-field
basis. Once the mode units is set, it carries over from field to field until a new mode units is entered.
Format: ^MUa,b,c