Field Parameter

Description:

The ^FP command sets the inter-character gap.

Format: ^FPd,g

Parameters:

d = not care

g: = additional inter-character gap(in dots)

Accepted Values:0 to 9999

^FD

^Field Data

Description:

The ^FD command defines the data string for the field. The field data can be any printable character

except those used as command prefixes(^ and ~).

Format: ^FDa

Parameters:

a = data to be printed

Accepted Values: any ASCII string up to 3072 characters.

Default Value: none – a string of characters must be entered.

Comments:

The ^ and ~ characters can be printed by changing the prefix characters – refer to the ~CC and ~CT

commands. The new prefix characters cannot be printed.

Characters with codes above 127,or the ^ and ~ characters can be printed using the ^FH and ^FD

commands.

^FS

Field Separator

Description:

The ^FS command denotes the end of the field definition.

Format: ^FS

Parameters:

^FS = field separator