Field parameter, Field data, Field separator – Dascom 7010 Programmers Manual ZPL User Manual
Page 12

12
Field Parameter
Description:
The ^FP command sets the inter-character gap.
Format: ^FPd,g
Parameters:
d = not care
g: = additional inter-character gap(in dots)
Accepted Values:0 to 9999
^FD
^Field Data
Description:
The ^FD command defines the data string for the field. The field data can be any printable character
except those used as command prefixes(^ and ~).
Format: ^FDa
Parameters:
a = data to be printed
Accepted Values: any ASCII string up to 3072 characters.
Default Value: none – a string of characters must be entered.
Comments:
The ^ and ~ characters can be printed by changing the prefix characters – refer to the ~CC and ~CT
commands. The new prefix characters cannot be printed.
Characters with codes above 127,or the ^ and ~ characters can be printed using the ^FH and ^FD
commands.
^FS
Field Separator
Description:
The ^FS command denotes the end of the field definition.
Format: ^FS
Parameters:
^FS = field separator