Zpl® command reference, Zpl® basic – Dascom 7010 Programmers Manual ZPL User Manual
Page 6

6
ZPL®
Command Reference
ZPL® Basic
^XA
Start Format
Description:
The ^XA command is used at the beginning of ZPL® code, It is the opening bracket and indicates
the start of a new label format.
Format: ^XA
Comments:
Label formats should start with the ^XA command and end with the ^XZ command to be in valid
^ZPL® format.
^XZ
End Format
Description:
The ^XZ command is the ending(closing)bracket. It indicates the end of a label format. When this
command is received, a label will be printed.
Format: ^XZ
Comments:
Label formats must start with the ^XA command and end with the ^XZ command to be in valid
ZPL® format.
^LH
Label Home
Description:
The ^LH command sets the label home position.
The default home position of a label is the upper-left corner (position 0,0 along the x-axis and
y-axis).This is the axis reference point for labels. Any area below and to the right of this point is
available for printing. The ^LH command changes this reference point. For instance, when working