c = number of data columns to encode
Accepted Values: 1 to 30
Default Value:1:2 (row-to-column aspect ratio)
The user can specify number of code-word columns given control over the width of the
symbol.
r = number of rows to encode
Accepted Values: 3 to 90
Default value:1:2 row-to-column aspect ratio.
The user can specify the number of symbol rows giving control over the height of the
symbol.
For example, with no row or column values enterd,72 code-word would be encoded
into a symbol of 6 columns and 12 rows. Depending on code-words, the aspect ratio
will not always be exact.
t = truncate right row indicators and stop pattern
Accepted Values: Y(perform truncation)and N(no truncation).
Default Value: N
Example1:
Example2:
Comments:
・If both columns and rows are specified, their product must be less than 928.
・No symbol is printed if the product of columns and rows is greater than 928.
^XA^BY2,3
^FO10,10^B7N,5,0,,,N
^FDPDF417^FS