beautypg.com

Dascom 7010 Programmers Manual ZPL User Manual

Page 43

background image

43

c = number of data columns to encode

Accepted Values: 1 to 30

Default Value:1:2 (row-to-column aspect ratio)

The user can specify number of code-word columns given control over the width of the

symbol.

r = number of rows to encode

Accepted Values: 3 to 90

Default value:1:2 row-to-column aspect ratio.

The user can specify the number of symbol rows giving control over the height of the

symbol.

For example, with no row or column values enterd,72 code-word would be encoded

into a symbol of 6 columns and 12 rows. Depending on code-words, the aspect ratio

will not always be exact.

t = truncate right row indicators and stop pattern

Accepted Values: Y(perform truncation)and N(no truncation).

Default Value: N

Example1:

Example2:

Comments:

・If both columns and rows are specified, their product must be less than 928.

・No symbol is printed if the product of columns and rows is greater than 928.

^XA^BY2,3

^FO10,10^B7N,5,0,,,N

^FDPDF417^FS

^XZ